VACUUM INTERRUPTER

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: ELCB
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZW32 ZKTD630/12-20
Poles Number
1
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection
Certification
ISO9001-2000, CE
Transport Package
Carton
HS Code
8535900090
Production Capacity
500000/Year

Product Description

Main Technical Data    
Rated voltage                                            kv 12
Rated current                                            A 630
Rated frequency                                         Hz 50
Rated short-time power frequency withstand voltage(1min)     kv 42
Rated lighting impulse withstand voltage                     kv 75
Rated short-circuit breaking current                         kA 12.5/16/20
Rated short-circuit making current(peak)                    kA 31.5/40/50
Rated operations of short-circuit breaking current interruption   times 30
Rated single capacitor bank breaking current                  A 400
Rated short-time withstand current                         kA 12.5/16/20
Rated peak withstand current                               kA 31.5/40/50
Rated duration of short-circuit                              s 4
Mechanical life                                           times 10000
Contact closing force due to bellows and atmosphere          N 70±40
Counterforce at rated contact stroke                          N 120±50
Three-pole simultaneity                                      μΩ 20
Shelf life                                                  years 20
Contact erosion limit                                       mm 3
Weight of moving parts                                                                             kg 0.7

Mechanical data required for matched vacuum switchgear
 
Rated contact stroke                                      mm 9±1
Average opening speed                                   m/s 1.0±0.25
Average closing speed                                    m/s 0.65±0.15
Added contact force                                       N 900/1300/1600±100
Contact bouncing duration at closing operation                ms 2
Contact bouncing bank amplitude of opening operation         ms 2
Three-pole simultaneity                                      ms 1

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.