12kv vacuum interrupter for indoor circuit breaker

Product Details
Customization: Available
Certification: ISO9001, CPRI
Protection: Corrosion Resistance
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
116
Year of Establishment
2006-09-05
  • 12kv vacuum interrupter for indoor circuit breaker
  • 12kv vacuum interrupter for indoor circuit breaker
  • 12kv vacuum interrupter for indoor circuit breaker
  • 12kv vacuum interrupter for indoor circuit breaker
  • 12kv vacuum interrupter for indoor circuit breaker
  • 12kv vacuum interrupter for indoor circuit breaker
Find Similar Products

Basic Info.

Model NO.
VTD32602GF
Installation
Vertical
Housing
ceramic
pole
3 poles
Transport Package
Pallet
Specification
3.2kgs
Trademark
feite
Origin
Wuahn China
HS Code
853590000
Production Capacity
50000

Product Description

Main Technical Data  
Rated voltage                                                               kv 12
Rated current                                                              A 1250/1600
Rated frequency                                                          Hz 50
Rated short-circuit breaking current                               kA 31.5
     
     
Rated short-time withstand and current(4s)                     kA 31.5
Rated single capacitor bank breaking current                  A 630
     
Short-time(1min) power-frequency withstand voltage        kv 48
Rated lighting impulse withstand voltage(peak)                kv 85
Machanical life                                                             times 30000
Contact closing force due to bellows and atmosphere      N 120±50
Counterforce at rated contact stroke                                 N 190±60
Circuit resistance at rated contact force                         μΩ ≤20
Shelf life                                                                        years 20
 
Contact erosion limit                                                                                         mm 3
Mechanical Data Required For Matched Vacuum Switchgear  
Rated contact stroke                                                    mm  9±1
     
Average opening speed                                                 m/s 1.0±0.25
Average closing speed                                                  m/s 0.65±0.15
Added contact force                                                    N 3150±200
Contact bouncing duration at closing operation ms  ≤2
Contact bouncing bank amplitude of opening operation mm  ≤2
Three-pole simultaneity ms  ≤1
12kv vacuum interrupter for indoor circuit breaker12kv vacuum interrupter for indoor circuit breaker12kv vacuum interrupter for indoor circuit breaker12kv vacuum interrupter for indoor circuit breaker12kv vacuum interrupter for indoor circuit breaker12kv vacuum interrupter for indoor circuit breaker12kv vacuum interrupter for indoor circuit breaker