High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear

Product Details
Customization: Available
Electricity Type: Vacuum
Number of Pole: /
Manufacturer/Factory & Trading Company
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
116
Year of Establishment
2006-09-05
  • High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear
  • High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear
  • High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear
  • High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear
  • High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear
  • High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Certifications
  • Packing
  • FAQ
Overview

Basic Info.

Model NO.
ZW32-40.5kV/1600A-31.5kA
Phase
3
Main Circuit Rating Voltage
40.5kV/1600A-31.5kA
Type
AC/DC Contactors
Name
Recloser
Shelf life
20years
Color
Silver, Copper
Afterserivce
Yes
Certification
ISO9001-2000
Transport Package
Pallet, Wooden
Specification
Circuit-Breaker Failure Protection
Trademark
Feite Brand
Origin
China
HS Code
8535900090
Production Capacity
22000PCS

Product Description

Product Description

40.5kV-1600A-31.5kA recloser



Main Technical Date

Parameter item  Unit Date
Rated voltage                                             kv 40.5
Rated current                                             A 630/1250/1600
Rated frequency                                          Hz 85 95/95
Short-time power frequencywithstand voltage(1min) (wet) (dryinterphase to ground /fracture    Kv 185
Rated lighting impulse withstandvoltage:(peak)interphase to ground /fracture Kv 20/25/31.5
Rated short-circuit breaking current            kA 63/80
Rated short-circuit making current(peak) kA 63/80
Rated short-time withstand current kA 25/31.5
4S short-time withstand current   opening-0.1s-closing opening-3s-closingopening -6s closing opening -60s recovery
Rated short-circuit breaking current times       times 30
Mechanical life tiems 1000
mechanism control voltage V AC/DC220
secondary circuit power frequency(1 min)                                        KV 2
Parameters of the mechanical characteristics                                            
Rated contact stroke mm 16±1
Contact over travel                                  mm 3±0.5
Opening speed                                 m/s 1.4-1.8
Closing speed                                      m/s 0.4-0.8
Contact bouncing duration at closing operation                 ms ≤5
Phase distance     mm 560±2
Three-pole simultaneity                          ms ≤2
Conductive circuit resistance of each phases μΩ <80
Closing time ms ≤100
Opening time ms ≤50
Weight kg 270
 

High Voltage Recloser For Outdoor Vacuum Circuit Breaker And SwithchgearHigh Voltage Recloser For Outdoor Vacuum Circuit Breaker And SwithchgearHigh Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear

Company Profile

ABOUT OUR COMPANY

Wuhan Feite Electric Co.,Ltd is located at Wuhan city, Hubei Province which is the Eastcenter part of China. lt is specialized in producing vacuum interrupter and vacuumembedded poles.The company has developed 1.14KV-40.5KV vacuum switch tubes morethan 300 types,which can be widely used for various vacuum circuit breaker, vacuumcontactors, vacuum load breaker switches, auto re-closers,RMU etc.The company has full sets vacuum producing and testing equipment,with annualproduction of 600,000 vacuum tube production capacity, As an ISO09001:2008 certifiedcompany,our production process strictly conforms to quality management system.Wuhan Feite Electric Co.,Ltd is always supply you good quality products with reasonableand competitive prices.



High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear


High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear


3> Different Types Vacuum Interrupter and Embedded Poles
High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear

 
Certifications

 


High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear

Vacuum Interrupter and Embedded Poles Stock
High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear


6> Company Introduction
High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear
 
Packing
High Voltage Recloser For Outdoor Vacuum Circuit Breaker And Swithchgear

 

FAQ

1. Precheck before putting it into use.
Check id packing is in good condition. Check the appearance of vacuum interrupter and
Whether it corresponds to the test certificate after uppacking. When shaking the interrupter, the ceramic envelop should be integrated.Power frequency withstand voltage should be tested before operating vacuum interrupter. Clean the surface with a dry colth or alcohol damped cloth before testing. The normal way for testing is an follows: when in the clearance between open contacts applies with 70 percent of rated power frequency withstand voltage within 1 min. The vacuum interrupter will be qualified if there is no sudden change and trip phenomena in the pointer of the vacuum interrupter.

 
2. Mounting of vacuum interrupter
a.Clean the surface of vacuum interrupter with cotton or alcohol dipped silk cloth before mounting. Meanwhile clean the conducting pole and surface of electric connection in order that the vacuum interrupter can have good electric contact with the equipment.b.The interrupter should be adjusted in the line with the equipment after mounting. The mechanical date related to the interrupter must meet the given specification.

3.In mounting, attention should be paid to the following:
a.When operating, guide unite unit must be provided for the interrupter. The coaxality of moving conducting pole and axial line of interrupter must meet the requirement. There should not be torque force applied on the bellow.
b. When mounting, it is forbidden to beat or strike the interrupter envelop with hard things in case crack may occur to cause air leakage.
c.Take care to assure that the conducting pole must be coaxial with interrupter, and that the conducting pole must be vertical on the face of fixed end
d.Take care not to disassemble the interrupter repeatedly to prevent screw from slipping. There should not be twisting on the moving conducting pole and over press on bellow to avoid that any torque force and scratch may occur to bellow to reduce its service life.
e.During mounting, the force applied on the face of both ends should not go beyond the static relief pressure stipulated in the specification.

 

4. Application.
a. Check the vacuum interrupter periodically by the way power frequency withstand voltage. For this, please see subclause
b. Periodically check how burnout is going on for contacts. When it comes to the burnout mark of moving conducting pole, it shows that the vacuum interrupter has finished its electrical endurance, and it should be replaced.